| Sign In | Join Free | My burrillandco.com |
|
DRL-III Thermal conductivity tester Thermal resistance tester ASTM D5470
1.use
It is mainly used to test the thermal resistance of thin thermal
conductors, solid electrical insulating materials, thermal
conductive silicone grease, resin, rubber, beryllium oxide
porcelain, alumina porcelain and other materials, as well as the
contact thermal resistance at the solid interface and the thermal
conductivity of the material. The detection material is solid
sheet, and the enclosed frame can detect powder state material and
paste material. Instrument reference standard: MIL-I-49456A
"Insulation sheet, heat conductive resin, heat conductive glass
fiber reinforcement"; GB/T 5598-2015 "Beryllium oxide porcelain
thermal conductivity determination method"; GB/T 29313-2017 "Test
method for heat conduction properties of electrical insulating
materials"; ASTM D5470-2017 "Test standard for Heat transfer Performance of Thin
Thermally Conductive Solid Electrical Insulating Materials", etc.
DRL-III thermal conductivity meter is designed and manufactured in
accordance with ASTM D5470-2017 standard. Our company has accumulated more than ten years of
experience in manufacturing and user practice, so that the product
performance continues to improve and mature. Servo motor control
precision automatic pressure, automatic thickness measurement
device, and connected to the computer to achieve automatic control.
The instrument adopts 6-point temperature gradient detection to
improve the test accuracy. A thermal protection device (thermal
protection of the sample) is added around the test rod in the test
head to reduce the influence of ambient temperature on the test.
Thermal resistance curves under different pressures can be
detected, and multiple parameters such as thermal conductivity,
thermal resistance and contact thermal resistance at the interface
can be measured by using optimized mathematical models. Using the
latest technology cold end temperature automatic compensation, no
longer need to add ice water compensation device.
Users can choose standard and small models (with the same
performance) according to the actual occupation area, saving
laboratory space.
Widely used in colleges and universities, scientific research
units, quality inspection departments and production plants of
material thermal analysis and detection.
DRL-III Thermal conductivity tester Thermal resistance tester ASTM D5470
2.Product Parameter
| sample size | Φ30mm or 20x20mm (standard configuration), other sizes can be customized |
| thermal conductivity test range | 0.001 ~ 50W/m.k, 0.001 ~ 300W/m.k, computer software automatic
switching range; |
| thermal resistance test range | 0.05 ~ 0.000005 M2.K/W |
| sample thickness | 0.001 ~ 50mm (standard configuration) , typical thickness: 0.02 ~ 20mm |
| thermal pole temperature control range | room temperature ~ 100ºC (standard configuration), room temperature
~ 299.99ºC, room temperature ~ 500ºC, temperature control accuracy
0.01ºC |
| cold pole temperature control range | 0 ~ 99.00ºC, temperature control accuracy 0.01ºC (equipped with
high precision, large capacity low temperature sink) |
| pressure range | 0 ~ 1000N, servo motor control, can accurately set the pressure
value, control accuracy 0.1N |
thickness range | 0 ~ 50.00mm, accuracy 0.1um, automatic thickness measurement |
| number of samples | 1 piece (multiple films) |
| test accuracy | better than 3% |
| Test methods | thermal resistance test under different pressures of samples, thermal conductivity test of materials, contact thermal resistance test, aging reliability test, compression performance test of materials, contact thermal resistance test between samples |
| power supply | 220V/50Hz; 500W |
computer automatic test, and realize data printing output
DRL-III Thermal conductivity tester Thermal resistance tester ASTM
D5470
3. Typical test materials
1, metal materials, stainless steel; 2, heat conduction silicone
grease;
3, thermal conductivity silicone pad; 4. Thermal engineering
plastics;
5, thermal tape (the sample is very thin and sticky, it is
difficult to make a regular single sample, one side is fixed with
transparent plastic and the other side is fixed with paper);
6, aluminum substrate, copper clad plate; 7, quartz glass,
composite ceramics;
8, copper foam, graphite paper, graphite sheet and other new
materials.
DRL-III Thermal conductivity tester Thermal resistance tester ASTM
D5470
4.complete set
1. One host computer;
2. A set of analysis software (Chinese and English versions);
3, HX-1005 precision low temperature constant temperature tank one
(temperature control accuracy 0.01ºC);
4, a Lenovo computer (users can choose);
5. Two standard samples;
6, a set of random accessories (fat, paste, powder test box, sample
convenient sheet forming stamping die each set).
DRL-III Thermal conductivity tester Thermal resistance tester ASTM
D5470
5. Dimensions and weight
1, host: standard landing model: (length × width × height)
550×450×1550mm, net weight: 100Kg,
Small desktop model: (length × width × height) 500×400×780mm, net
weight: 60Kg;
2, precision low temperature constant temperature tank: (length ×
width × height) 300×350×530mm, net weight: 35Kg.
DRL-III Thermal conductivity tester Thermal resistance tester ASTM
D5470
6. Technical services
1, one year free warranty, long-term technical services, software
lifetime free upgrade.
2. Free on-site installation and debugging throughout the country.
All over the country has the company's mobile technical personnel,
can provide technical services.
|