Sign In | Join Free | My burrillandco.com
Home > Lab Test Machine >

Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

DONGGUAN LONROY EQUIPMENT CO LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment from wholesalers
     
    Buy cheap Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment from wholesalers
    • Buy cheap Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment from wholesalers
    • Buy cheap Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment from wholesalers
    • Buy cheap Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment from wholesalers
    • Buy cheap Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment from wholesalers
    • Buy cheap Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment from wholesalers
    • Buy cheap Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment from wholesalers

    Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

    Ask Lasest Price
    Brand Name : Lonroy
    Certification : ISO ASTM CE
    Price : Negotaible
    Delivery Time : 5-8 work days
    Payment Terms : L/C,D/A,D/P,T/T,Western Union
    Supply Ability : 200
    • Product Details
    • Company Profile

    Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment

    Battery Recovery Discharge Testing Machine Single Cell Recovery Discharge Equipment Recycling Discharge Device

    Product Description

    I. Specifications and Quantity

    1. Battery discharge testing equipment, each unit consists of * main channels (customizable according to requirements).

    2. Each set of equipment includes discharge main channels, battery racks, battery connection lines, and battery clamps.

    3. The battery clamps use crocodile clips, which can be applied to both cylindrical and pouch batteries.

    II. Equipment Application Scope and Function Introduction

    1. Equipment application scope: Mainly used in the discharge process during the recycling of single lithium-ion batteries.

    2. Function introduction:

    1) The entire set of equipment includes discharge equipment, battery racks, output lines, and battery clamps. The battery connection lines output by the discharge equipment are fixed according to the battery position and are welded to the battery clamps at the end, used to hold the battery tabs.

    2) Each main channel can simultaneously connect 20 batteries. The batteries are connected in a single-channel parallel manner, and discharge starts and stops simultaneously. Each cabinet has 5 main channels, and each main channel operates independently.

    3) Multiple batteries can be discharged through one channel. The optimized internal circuit can effectively avoid short circuits or reverse connections of a single battery or the uncontrollable discharge of all batteries connected in series.

    4) Automatic equalization discharge of batteries within one channel can be completed. The discharge current of batteries with higher voltage automatically increases (up to 20A), and the discharge current of batteries with lower voltage automatically decreases. This enables the discharge of multiple batteries at a faster speed, and when the voltage of all batteries reaches the set termination value, the current stage stops, allowing the online discharge time of the batteries to be extended and achieving a more ideal discharge effect.

    5) The voltage of all batteries can be collected and recorded, and the voltage of the same channel is automatically compared. It can dynamically display the number data of the highest and lowest voltage, making it easier to identify uncharged batteries.

    6) The equipment in all channels is connected to the PC through communication lines, and the operation and stop of the equipment are controlled by the upper computer software. Detailed voltage readings of each battery can be viewed.

    7) Before starting, the voltage of each single battery is checked. When the voltage of a battery at a certain terminal is "below 0.5V", the equipment defaults to no battery, and when the voltage is "above 0.5V", it defaults to having a battery. The battery with this number is set to an online state. When the number of online batteries is consistent with the set number, discharge operation begins. Otherwise, it is considered a battery contact fault, and an alarm is triggered to pause.

    8) During the discharge process, when a battery discharges to the set termination voltage, a set of data is automatically generated to record the termination data of this battery. The battery will continue to be discharged online until all batteries reach the set termination voltage or the set testing time.



    Battery Recovery Discharge Testing Machine Single Cell Recovery Discharge Equipment Recycling Discharge Device

    Technical Specification

    Main channel number

    * Unit / Cabinet

    Auxiliary channel number

    20 units / Main channel

    Energy consumption parameters

    Discharge uses electronic load, discharge energy is converted into heat energy

    Working mode

    Constant current discharge, constant power discharge, constant resistance discharge, multi-stage discharge, multi-stage cyclic discharge, standstill, pause

    Stage termination condition

    Time, number of individual cells (set quantity), ampere-hour

    Real-time display

    1. The main interface of the upper computer can display current, individual cell voltage, time, stage, mode, Ah, Wh in real time;

    Time display resolution

    1 second

    Timing accuracy

    ±10 seconds / 24 hours

    Stage time setting range

    1 second - 1000 hours;

    Stage setting range

    1 - 200 stages

    Record interval setting range

    1 second - 1000 hours (sampling record interval can be set stage by stage)

    Number of PC storage programs

    Dependent on the storage space of the PC

    Number of cycles

    Maximum 65535

    Cycle nesting

    Maximum 6 layers

    Discharge voltage range

    *V~*V (The online battery voltage is all above 1.5V, ensuring the setting current)

    Total discharge current range

    0A~*A

    Total current accuracy

    ±0.5% F.S (1% - 100% range)

    Total current resolution

    0.01A

    Single cell voltage sampling point

    20 per channel

    Single cell voltage sampling range

    0V-5V

    Single cell voltage resolution

    0.001V

    Single cell voltage accuracy

    ±0.5% F.S (1% - 100% range)

    Interface and communication method

    Communicates with PC via 485. It can be connected via USB port or serial port. One PC can control 200 channels.

    Quality Battery Discharge Testing Machine with IP56 Protection 220V and 380V Voltage for Single Cell Recovery Discharge Equipment for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: DONGGUAN LONROY EQUIPMENT CO LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)