    Wheelchair Seat Pad Flame Retardancy Testing Instrument Wheelchair Backrest Fire Resistance Tester

    Ask Lasest Price
    Brand Name : Lonroy
    Model Number : LR-A149
    Certification : ISO ASTM CE
    Price : Negotaible
    Payment Terms : L/C,D/A,D/P,T/T,Western Union
    Supply Ability : 200
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Wheelchair Seat Pad Flame Retardancy Testing Instrument Wheelchair Backrest Fire Resistance Tester

    Wheelchair Seat Pad Flame Retardancy Testing Instrument Wheelchair Backrest Fire Resistance Tester

    Main application

    The wheelchair seat (backrest) pad fire resistance testing instrument is used to test the fire resistance performance of wheelchair seat (backrest) pad materials against cigarettes and matches.

    Applicable standards

    GB/T 18029-2000 Requirements and testing methods for fire resistance of wheelchair seat (backrest) pads

    Overall laboratory plan

    1. The test frame should be placed in a fume hood (provided by the user), with the control box outside the fume hood. During the experiment, the operator operates the control box, and the test frame conducts a combustion test in a closed environment within the fume hood. The fume hood is connected to the ventilation duct of the laboratory for smoke exhaust.

    The ventilation system of the fume hood controls the air flow rate in the test space to make the wind speed on the surface of the test frame between 0.02 and 0.2 m/s, and the air flow rate can be adjusted and controlled.

    (Note: The igniter is a handheld operation igniter. The ignition time is within 20 seconds, and the observation window of the fume hood is opened to facilitate the ignition operation; after ignition, the observation window is closed, and the combustion is carried out in a closed environment. Observe the experimental state. The entire process should maintain the air flow rate within the required range.)

    2. Constant temperature water bath box:

    1) Heating tube heating.

    2) The test box is equipped with heating devices, refrigeration devices and circulating water pumps to ensure uniform temperature of the constant temperature water bath at 20℃, with a control accuracy of ±2℃.

    3) PID temperature control regulation. Temperature setting and measurement: digital display.

    4) The water tank has a closed circulation device to mix evenly.

    5) The box body has upper and lower water functions.

    6) The box body is designed with full stainless steel, has corrosion resistance, has a long service life, the test area surface is added with insulation materials, and the insulation effect is good. Copper tubes are laid in the water bath box.

    7) The box body is equipped with power overload and short circuit protection.

    8) Power supply: 220V 50Hz.


    Technical specifications

    Dimensions of the stainless steel combustion tube

    Outer diameter (8 ± 0.1) mm, inner diameter (6.5 ± 0.1) mm, length (200 ± 5) mm

    Compliance with standards and additional components

    Fully in accordance with GB/T 18029-2000 and ISO7176-16: 1997 requirements; equipped with a fixture bar for holding small samples

    Back frame dimensions

    Length: (450 ± 2) mm; Height: (300 ± 2) mm

    Seat frame dimensions

    Width: (450 ± 2) mm; Depth: (150 ± 2) mm

    Ignition time

    Can be set from 0 to 99.99 seconds, with an accuracy of 0.01 seconds

    Measurement of progressive smoldering and flame combustion time

    Measurable range: 0 to 1 hour; Accuracy: ± 1 second

    Gas flow meter (at 20°C)

    Flow rate: (45 ± 2) mL/min; detachable for calibration; outlet pressure adjustable

    Fuel gas

    Propane; gas tank and gas provided by the user

    Time recording and display

    Ignition time, progressive smoldering time, and flame combustion time are automatically recorded and displayed digitally

    Gas flow control system

    Flow rate of combustible gas flowing towards the ignition source of the gas flame and outlet pressure can be adjusted

    Gas leakage alarm device

    The instrument is equipped with a gas leakage alarm device

    Constant temperature water bath box

    Equipped with inlet and outlet air ports connected to external gas pipes; interior with coiled copper tube; temperature settable and adjustable; temperature calibration device at the outlet; connecting hose between flow meter and combustion tube: 2.0 - 3 meters long, inner diameter (7 ± 1) mm; water bath temperature controlled at (20 ± 2) °C

    Laboratory temperature requirement

    Required to be balanced at (20 ± 2) °C

    Burning droplets collection tray

    The equipment is equipped with a collection tray for burning droplets, convenient for cleaning

    User-provided items

    Masks, goggles, work clothes, etc. (to be provided by users)

    Working power supply

    AC 220V, 50Hz


    Quality Wheelchair Seat Pad Flame Retardancy Testing Instrument Wheelchair Backrest Fire Resistance Tester for sale