Sign In | Join Free | My burrillandco.com
Home > Ceramic Tester >

LRH-400 Thermal Conductivity Tester Heat Shield Plate Method

    Buy cheap LRH-400 Thermal Conductivity Tester Heat Shield Plate Method from wholesalers
     
    Buy cheap LRH-400 Thermal Conductivity Tester Heat Shield Plate Method from wholesalers
    • Buy cheap LRH-400 Thermal Conductivity Tester Heat Shield Plate Method from wholesalers
    • Buy cheap LRH-400 Thermal Conductivity Tester Heat Shield Plate Method from wholesalers

    LRH-400 Thermal Conductivity Tester Heat Shield Plate Method

    Ask Lasest Price
    Brand Name : Lonroy
    Model Number : LRH-400
    Certification : Includes Calibration Certification
    Price : Negotaible
    Payment Terms : L/C,D/A,D/P,T/T,Western Union
    Supply Ability : 200
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    LRH-400 Thermal Conductivity Tester Heat Shield Plate Method

    LRH-400 Thermal Conductivity Tester Heat Shield Plate Method

    1.Description:
    The thermal conductivity of materials is an important parameter for studying the thermal physical properties of materials. This instrument adopts the principle of the heat shielding plate method, meeting the high-precision testing requirements for material thermal conductivity of the material testing research departments.The instrument is composed of a high-precision voltage stabilizing power supply, a temperature measuring instrument, a central calorimeter heater, a heat protection plate heater, a constant temperature water bath, and a computer testing system.
    1. Test head components: calorimetric plate, heat protection plate, cold plate.
    2. Heating system: Heat insulation plate temperature heater and metering power heater.
    3. Temperature control of cold plates: Constant temperature water bath.
    4. Temperature measurement system: Utilizes digital high-precision instruments to ensure accuracy and stability, and enables internal compensation for the zero point.
    5. The power measurement is carried out using a high-precision regulated power supply for heating, with an accuracy better than 0.1%.
    6. Computer test components: Computers, communication components and test software.
    DRH-ZD-400 features automatic pressure application and automatic thickness measurement functions. It can measure the thermal conductivity and thermal resistance under different pressure conditions, and is highly suitable for materials with compressibility:
    a. Use high-precision displacement sensors and connect them to a computer for automatic thickness measurement. The measurement range is 0 - 80mm, with a resolution of 0.01mm.
    b. It can automatically apply pressure to measure the thermal conductivity under different pressure conditions. The pressure range can be adjusted from 0 to 1000N, with a resolution of 0.1N.
    2.Standard

    GB/T3399 "Test Method for Thermal Conductivity of Plastics - Thermal Shield Plate Method", GB/T3139-2005 (Test Method for Thermal Conductivity of Fiber Reinforced Plastics) (Test Method for Thermal Conductivity of Fiberglass Reinforced Plastics),
    GB/10294-2008 "Determination of Steady-State Thermal Resistance and Related Properties of Insulation Materials - Protective Heat Plate Method", etc. The main tests include plastics, glass, fibers, foams, insulation materials, etc. It is widely used in large and medium-sized colleges, research institutions, quality inspection departments and production plants for material analysis and testing.

    3.Feature:
    1. Automatic thickness measurement: Utilizing high-precision displacement sensors for measurement and connecting to a computer for automatic thickness measurement, thereby reducing human error.
    2. Automatic Pressurization System: The system automatically applies pressure. It enables the measurement of thermal conductivity under various pressure conditions. This method is more scientific, data-driven, and has higher repeatability compared to manual pressure application.
    3. Various measurement types: In addition to measuring hard plates, by selecting various accessories from the company, it is possible to measure a wide range of special materials. For example: granular materials, loose materials, soil, etc.

    4.Technical Parameter.

    Thermal Conductivity Range0.0010~3.0000 W/(m·K) (4 decimal places display)
    Measurement Accuracy≤ ±3%
    Hot Surface Temperature
    • RangeRoom Temperature ~ 95°C
    • Resolution0.01°C
    Cold Surface Temperature
    • Range0 ~ 60°C
    • Resolution0.01°C
    • Control MethodConstant Temperature Bath
    Power Supply220V/50Hz; Power ≤ 2kW
    Calorimetric Power Supply
    • Voltage0-30V, Resolution: 0.0001V
    • Current0-3A, Resolution: 0.0001A
    Automation SystemComputer-controlled testing with data printout
    Sample Dimensions400 × 400 × (5-80) mm
    Quality LRH-400 Thermal Conductivity Tester Heat Shield Plate Method for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: DONGGUAN LONROY EQUIPMENT CO LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)