Sign In | Join Free | My burrillandco.com
Home > Ceramic Tester >

LRS Series 1000ºC Thermal Conductivity Tester Guarded Plate Heat Flow Meter Method

    Buy cheap LRS Series 1000ºC Thermal Conductivity Tester Guarded Plate Heat Flow Meter Method from wholesalers
     
    Buy cheap LRS Series 1000ºC Thermal Conductivity Tester Guarded Plate Heat Flow Meter Method from wholesalers
    • Buy cheap LRS Series 1000ºC Thermal Conductivity Tester Guarded Plate Heat Flow Meter Method from wholesalers
    • Buy cheap LRS Series 1000ºC Thermal Conductivity Tester Guarded Plate Heat Flow Meter Method from wholesalers
    • Buy cheap LRS Series 1000ºC Thermal Conductivity Tester Guarded Plate Heat Flow Meter Method from wholesalers

    LRS Series 1000ºC Thermal Conductivity Tester Guarded Plate Heat Flow Meter Method

    Ask Lasest Price
    Brand Name : Lonroy
    Model Number : LRS Series
    Certification : Includes Calibration Certification
    Price : Negotaible
    Payment Terms : L/C,D/A,D/P,T/T,Western Union
    Supply Ability : 200
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    LRS Series 1000ºC Thermal Conductivity Tester Guarded Plate Heat Flow Meter Method

    LRS Series 1000ºC Thermal Conductivity Tester Guarded Plate Heat Flow Meter Method

    1.Description
    This instrument is a thermal conductivity tester for thermal insulation materials developed from our LRS-2 water flow plate method thermal conductivity tester. Compared with LRS-2, it has improved resolution and automation, shortened test time, easier maintenance, and more reliable instrument performance. This instrument uses the protective heat flow meter method to detect the thermal conductivity of thermal insulation materials at high temperatures. It is suitable for testing the thermal conductivity of refractory insulation, ceramic fibers, felt, textiles, boards, bricks and other materials at different temperatures. It is widely used in material analysis and testing in colleges and universities, scientific research institutions, quality inspection departments and production plants.
    2.Standard:

    This instrument reference standard: ASTM C518-10 Test method for determining steady-state heat flux and heat transfer characteristics by heat flow meter method; ISO 8301:1991 and GB/T 10295-2008 Determination of steady-state thermal resistance and related characteristics of thermal insulation materials (heat flow meter method), etc.

    3.Technical Parameter.

    Specification ItemLRS-4ALRS-3ALRS-3B
    Thermal Conductivity Range0.001-3 W/m·K0.0010-3 W/m·K0.0010-3 W/m·K
    Measurement AccuracyBetter than ±5%±5%±5%
    Hot Surface Temp. Range200-1200°C100-1200°C100-1200°C
    Calorimetric Temp. Control MethodSemiconductor coolingSemiconductor coolingSemiconductor cooling
    Guard Temp. Control MethodSemiconductor coolingSemiconductor coolingSemiconductor cooling
    Calorimetric Plate Size75×75 mm75×75 mm75×75 mm
    Heat Flux Meter Size75×75 mm75×75 mm75×75 mm
    Specimen Temp. Points4 points4 points4 points
    Loading/Unloading MethodElectric loading--
    Pressure Range0-500 N--
    Thickness Range0-120 mm--
    Thickness CorrectionReal-time correction by displacement meter--
    Specimen AtmosphereAirAir-0.095 MPa; Atmosphere protection
    Specimen Size230×230 ~ 250×250 mm; Thickness 10~100 mm200×200 ~ 250×250 mm; Thickness 10~100 mm200×200 ~ 250×250 mm; Thickness 10~100 mm
    Measurement ControlFully automated PC testing, data processing, report generation, and printout.Fully automated PC testing, data processing, report generation, and printout.Fully automated PC testing, data processing, report generation, and printout.
    Power Supply220V, 50Hz, ≤5 kW220V, 50Hz, ≤5 kW220V, 50Hz, ≤5 kW
    Standard Configuration• LRS-4A main unit
    • Software suite
    • Test thermocouples
    • Rubber water hose (requires tap water connection; optional water bath upgrade available at extra cost)
    • PC (can be user-provided)
    • LRS-3A main unit
    • Software suite
    • Test thermocouples
    • Rubber water hose (requires tap water connection; optional water bath upgrade available at extra cost)
    • PC (can be user-provided)
    • LRS-3B main unit
    • Software suite
    • Test thermocouples
    • Rubber water hose (requires tap water connection; optional water bath upgrade available at extra cost)
    • Vacuum sealing device
    • Vacuum pump
    • PC (can be user-provided)
    Optional FeaturesMulti-layer testing (requires additional thermocouple per layer, extra cost).Multi-layer testing (requires additional thermocouple per layer, extra cost).Multi-layer testing (requires additional thermocouple per layer, extra cost).
    Quality LRS Series 1000ºC Thermal Conductivity Tester Guarded Plate Heat Flow Meter Method for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: DONGGUAN LONROY EQUIPMENT CO LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)