    408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber

    Ask Lasest Price
    Model Number : LR-B001
    Brand Name : Lonroy
    Certification : ISO ASTM CE
    Price : Negotaible
    Delivery Time : 5-8 work days
    Payment Terms : L/C,D/A,D/P,T/T,Western Union
    Supply Ability : 200
    • Product Details
    • Company Profile

    408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber

    408L 1000L Programmable Temperature Humidity Chamber Environment Test Chamber

    GB11158

    High Temperature Test Chamber Technical Condition

    GB10589-89

    Low Temperature Test Chamber Technical Condition

    GB10592-89

    High-low Temperature Test Chamber Technical Condition

    GB/T10586-89

    Damp Heat Test Chamber Technical Condition

    GB/T2423.1-2001

    Low Temperature Test Chamber Test Methods

    GB/T2423.2-2001

    High Temperature Test Chamber Test Methods

    GB/T2423.3-93

    Damp Heat Test Chamber Test Methods

    GB/T2423.4-93

    Alternating Damp-Heat Test Methods

    GB/T2423.22-2001

    Temperature Changing Test Methods

    IEC60068-2-1.1990

    Low Temperature Test Chamber Test Methods 

    IEC60068-2-2.1974

    High Temperature Test Chamber Test Methods

    GJB150.3

    High Temperature Test Methods

    GJB150.4

    Low Temperature Test Methods

    GJB150.9

    Damp Heat Test Methods

    1. Item

    2. Model

    Constant Temperature and humidity test chamber

    408L,1000L

    3. Function

    It simulates the products in the chamber where the climate condition of different temperature and humidity, such as high-low operation and storage, temperature cycling, high-low temperature and high-low humidity, moisture condensation etc. to check its adaptability and changing performance.

    It’s required to conform to international regulation (IEC, JIS, GB, MIL…) to reach the consistency (including test schedule, condition, method) under the international standard.

    4. Sample application

    The chamber applies to:

    compatibility test for store, transportation and application of electric, electronic products, unit components, parts and other materials under high or low temperature.

    The following samples are prohibited to be tested and stored:

    - Inflammable , explosive and other volatile substances;

    - Corrosive substance;

    - Biont;

    - Strong electromagnetic emission source.

    5. Volume, size & weight

    5.1. Volume

    5.2. Internal size

    5.3. Exterior size

    5.4. Weight

    408L 1000L

    W 600 x H850 x D800mm W 1000 x H1000 x D1000mm

    W900 x H1810 x D1800mm W1300 x H2000 x D2100mm

    400KG 600KG

    6. Performance

    6.1. Test condition

    Temperature:+25℃, Humidity: ≤85%, no samples in the chamber

    6.2. Test method

    GB/T 5170.2-1996 Temperature test chamber

    GB/T5170.5-1996 Temperature and humidity test chamber (only temperature and humidity)

    6.3. Temperature range

    -40℃→+150℃ (can customize -70℃)

    6.4. Temperature fluctuation

    ±0.5℃

    6.5. Temperature accuracy distribution

    ±2.0℃

    6.6. Humidity range

    20%98%R.H (temperature at 20℃-85℃)

    6.7. Humid. fluctuation

    ±2.5%R.H.

    6.8. Humidity accuracy distribution

    ±3.0%.

    6.9. Heat-up time

    -40℃ → +150℃ Heat up for 2-4.0℃/min

    6.10. Cooling time

    +150℃→ -40℃ Cooling for 0.7-1.0℃/min (customzie 3℃/min)

    6.11. Load condition

    Testing space is not more than 3/4 of the total space, no heating

    6.12. Sample holder

    Stainless steel punching stencil

    6.13. Relative humidity and temperature control range (refer to fig.)

    408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber

    6.14. Meet the technical standards

    GB/T 2423.1-2001 Test A: Low temperature test method

    GB/T 2423.2-2001 Test B: High temperature test method

    GJB 150.3-1986 High temperature test

    GJB 150.4-1986 Low temperature test

    IEC68-2-1 Test A: Cold

    IEC68-2-2 Test B: Dry heat

    GB11158 “Technical Conditions for High Temperature Test Chamber ”

    GB10586-1 “Technical conditions for Damp heat test chamber ”

    GB/T 2423.2 Basic environmental testing procedures

    for electric and electronic products B: High temperature test method”.

    GB/T 2423.3 “Basic environmental testing procedures

    for electric and electronic products Ca: Constant damp heat testing method” etc.

    7. Structure characteristics.

    7.1. Insulated enclosure structure

    408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber

    External material: SUS304 or stoving varnish or coating outside

    Inwall material: SUS304

    Insulation material of box body: flame retardant fire rigid polyurethane foam

    Door thermal insulation material: flame retardant fire rigid polyurethane foam

    7.2. Air conditioning channel

    Centrifugal fan:

    Heater, evaporimeter, outfall, temperature sensor

    7.3. Test chamber standard

    Window 330x450x40mm 3 vacuum layers

    Anti-explosion handle

    Door hinge: SUS #304

    Lamps in the chamber: 11W

    Access port: φ50mm or φ100mm 1pc or more.

    7.4. Door

    Single door, open from left, handle is at right; With viewing window: W300xH450mm, lamp window/condensation prevention thermal device

    7.5. Controller

    Control screen, overtemperature protection setting

    7.6. machine room

    Refrigeration units , water pans , outfall

    7.7. control cabinet for power distribution

    Switchboard fan, ventilator

    7.8. Heater

    Heating system: cycling heating from finned-tube Stainless steel electric heater

    7.9. Humidifier

    Oven humidification system, cycling winding system

    7.10. Power line hole and outfall position

    located at the back of chamber

    8. Cooling system (Binary cascade refrigeration)

    8.1. Cooling compressor

    Tecumseh (France)

    408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber

    8.3. Evaporator

    408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber

    fins-tube evaporator

    8.4. Condensator

    Air-coolled tube-type condensator

    408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber

    8.5 Expansion system

    Refrigeration system of volume control (capillary)

    8.6 Evaporative condenser

    Stainless steel brazing plate-type heat exchanger

    408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber

    8.7 Chiller control

    Operation of cooling machine can be adjusted automatically by control system according to the test condition

    evaporating pressure adjustable valve

    Cooling loop of compressor

    8.8 Freezing medium

    408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber

    R404a (Eco-friendly, Ozone loss rate at 0)

    9 Controller

    408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber

    Independent R&D software (Taiwan)

    9.1 Temperature and Humidity controller

    Imported 7.0 inch LCD touch screen control, programmable of temperature and humidity; 100 groups of program and 1000 groups of memory, each for 99hrs 59min and can be set as required with groups of PID control function.

    9.2 Controller specifications

    Precision: Temp. ±0.11digi, humid.: ±1%R.H1digit

    Distinguishability: Temp.: ±0.01, humid.:±0.1%R.H.

    slope temperature; 0.19.9 adjustable.

    With warning function and up& down limitation standby

    9 groups of PID control parameters and PID auto-calculation.

    Dry and damp ball with auto correction.

    9.3 Function of page display, program volume and control function

    - Touch screen operation, no need to input by key pressing;

    - Temp. and Humid. Set (SV) with true (PV) value shown.

    - Display of current program No., phase, time left and cycling times.

    - Run the operation of accumulative time.

    - Program set value of Temp.& humid. shown as curve;

    - At least 5 phase of temp. & humid, time can be input on the sole program editing page.

    - Language can be switched between English and Chinese;

    - Fault page shown;

    - Back light adjustable of screen;

    - Protection function can be set by time, TIMER can be turn off by manual;

    - Program groups available: 100 max. PATTEN.

    - Memory volume available: 1000 SEGMENTS.

    - Repeat executive command: up to 90 times for each command.

    - Program with editing, cancel and insert available;

    - Time set of SEGMENTS: 090Hour59Min;

    - Module device controlled by program;

    - Electricity cut memory, with auto start-up and executive program function after switch on;

    - program execution with display of curve diagram;

    - With auto adjustable freeze function;

    - Reservation of start-up and turn-off available;

    - Data and time adjustable;

    - Key-pressing and page lock (LOCK) available.

    10 Safety protection device

    a) Cooling system

    - compressor overheated

    - compressor overflowed

    - compressor overpressed

    - condensate fan overheated

    - oil pressure protection of compressor

    b) Test chamber

    Adjustable overheat

    Air conditioning channel overtemperature limit

    Wind motor overheated

    c) Other

    - phase sequence and open phase protection of main power supply

    - leakage protection

    - heating, humidification and Dry burning-resistant protection

    - overload and short circuit protection

    - overtemperature outage protection

    11 Other equipped parts

    a) power control contactor of sample testing

    Contactor of relay control: within AC220V, 2A (contactor closed under normal running, when chamber stops or of malfunction, contactor open).

    b) leakage breaker of main power supply

    AC220V, 50HzGrounding wire.

    12 Accessories

    a) Power

    (Standard)

    Five core single-phase three-wire and 1piece of protection grounding wire (optional)

    b) Access port

    φ50mm, φ80mm, φ100mm, φ120mm available according to your requirement and cab be customized on the premise that not affect the machine performance.

    c) USB interface (Standard)

    All the history curve and history data can be downloaded from controller as Excel or JPG according to date.

    408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber

    408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber

    d) Remote Control System (optional)

    408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber

    13 Transportation

    The chamber as a unitary to be transported

    a) Delivery size

    b) Weight

    Max. size (package not included): refer to “exterior size”

    Max. delivery weight (package not included): refer to “Weight”

    14 Usage requirements

    Assured by users as below requirements

    14.1 Installation position

    - With leveling ground and good ventilation;

    - No strong shock near the chamber;

    - No strong electromagnetic field near the chamber

    - No inflammable , explosive , corrosive material and dust

    - Surrounding size for chamber operation and maintenance:

    408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber


    A: not less than 10cm

    B: not less than 60cm

    C: not less than 60cm

    D: 225 type: not less than 80cm

    408 type: not less than 90cm

    1000 type: not less than 120cm

    14.2 Condition

    Temperature: 530

    Humidity: ≤85%

    Air pressure: 86kPa106kPa

    14.3 Tap water: only for damp heating equipment with pure water machine

    Water flow ≥200kg/h, pressure: 0.1Mpa ~ 0.25Mpa.

    Tap water conforms to GB 5749-1985 drinking water standard; Remark: equipped with DN15 male adapter of pure water machine

    14.4 Power supply condition

    Total power

    Max. current

    Voltage

    - AC220V + Protection grounding

    - Voltage fluctuation range: AC(220±10%) V

    - Frequency fluctuation range: (50±0.5)Hz

    - Resistance of protection grounding wire less than 4Ω.

    - It’s required to equipped with air or motive switch of corresponding capacities, which is also used only for the chamber

    3.8 KW

    16A

    380V

    Quality 408L 1000L Environment Test Chamber Programmable Temperature And Humidity Chamber for sale