Sign In | Join Free | My burrillandco.com |
|
Ask Lasest Price | |
Brand Name : | LONROY |
Model Number : | LR-V15 |
Certification : | CE ISO ASTM |
Payment Terms : | ,L/C,D/A,D/P,T/T,Western Union |
Supply Ability : | 200 pieces |
Delivery Time : | 5-8 work days |
Photovoltaic Module Testing Machine UV Aging Test Chamber Solar Panel Testing Machine IEC 61215
1. Product Description
Purpose of UV pretreatment tester: The UV aging tester for
photovoltaic modules simulates the damage caused by the UV rays in
sunlight when the modules are exposed outdoors for a long time.
This equipment only takes a few days or weeks to reproduce the
anti-UV aging performance of the module-related materials that
takes months or years outdoors.
Applicable standards for UV Aging Test Chamber : IEC 61215, IEC 61646 standard requirements
Materials used | high-quality materials that can completely block ultraviolet rays, have good sealing and thermal insulation propertie |
Total UV irradiation area of the equipment | greater than 2000mm×2000mm, meeting the requirements for testing two 2m×1m components at the same tim |
Light source life | The system uses a single set of xenon lamps with a life of about 1000 hours. A set of spare parts is provided when the equipment is delivered, with a service life of more than 2000 hours |
Relative energy ratio of single lamp UVA and UVB | UVB accounts for about 3% to 10% of the total energ |
Irradiation intensity | The irradiation intensity of the wavelength of 280nm to 385nm can
reach about 100W/m², 280nm to 320nm <=10%, ensuring that the
test cycle is shortened as much as possible |
Irradiation uniformity | better than ±15 |
Real-time monitoring and display of UVA and UVB intensity | |
One UVA (320nm to 385nm) and one UVB (280nm to 320nm) fiber optic probe | |
Component surface temperatur | 60ºC±5ºC |
Temperature resolution | 0.1ºC |
Ozone | Almost no ozone is generated |
Lighting method | top lighting, the component test plane is perpendicular to the
light source |
Touch screen control and real-time monitoring, automatically cut off the light source when the set value is reached | |
Real-time graphical display of component surface temperature, measurement accuracy ±0.1ºC |
![]() |