Sign In | Join Free | My burrillandco.com |
|
Ask Lasest Price | |
Brand Name : | Lonroy |
Model Number : | Konica Minolta |
Certification : | Includes Calibration Certification |
Price : | Negotaible |
Payment Terms : | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability : | 200 |
Delivery Time : | 5-8 work days |
Konica Minolta High-Precision Handheld Colorimeter
1.Description
The basic composition of spectroscopic tester can be divided into
light source and illumination system, collimation system,
dispersion system, imaging system and receiving, detection and
display system 5 parts, of which the collimation system and
dispersion system can be collectively referred to as the
spectroscopic system. The light emitted from the light source is
irradiated on the object to be measured, and the light reflected
from the surface of the object to be measured is directed to the
incident slit after reflecting several times on the inner wall of
the integrating sphere, and the light contains material spectral
information. The illumination system (in this case the integrating
sphere) transfers the light energy reflected from the surface of
the object to the collimation system.
The collimation system generally consists of an incident slit and a
collimating objective lens, and the beam emitted from the slit
passes through the collimation system and becomes parallel to the
dispersion system. The dispersive system uses a dispersive element
(in this case, a flat grating) to separate the incident parallel
light into monochromatic light. Imaging system is the role of the
spatially dispersed wavelengths of monochromatic light convergence
in the focal plane of the imaging mirror, forming a series of
wavelengths arranged according to the slit monochrome image. The
receiving system and the display system receive the spectral energy
on the focal plane and output the color measurement results in the
form of data after data processing.
Compared to filter-type colorimeters, spectrophotometric
colorimeters are more accurate and sensitive to color, and are more
suitable for measuring the absolute value of a sample's color in
addition to the color difference.
The latest series of CM-23d, CM-25d and CM-26d integrating sphere
type portable spectrophotometric colorimeter launched by KONICA
MINOLTA can be used in various fields. In addition to the
advantages of easy operation and fast measurement, they also have:
* Compact structure, light weight, ergonomic design, comfortable
grip, other equipment difficult to detect the position can also be
flexible measurement.
* Equipped with a viewfinder for easy positioning and alignment.
* Simplified operation process, intuitive and easy to use
* Built-in simple mode, only need to turn on the power, press the
button 3 times, you can measure the color difference between the
sample and the target color.
* 2.7" display is intuitive and easy to read.
* Each measurement takes only 0.7 seconds; the shortest measurement
interval is 1.5 seconds (normal mode); when averaging, the
automatic averaging function further shortens the measurement
interval.
As the agent of Japan Minolta series colorimeter, we have rich
experience in helping customers to solve color problems, and we can
provide free door-to-door installation, training and later
calibration services
2.Technical Parameter
Order information → technical parameter ↓ | CM-23d | CM-25d | CM-26d | ||
Lighting/observation system | Di: 8°, de: 8° (diffuse lighting: 8° observation) SCI (including specular reflection light) / SCE (excluding specular reflection light); mode can be switched | ||||
sensor | Dual 32-element silicon photodiode array | Dual 40-element silicon photodiode array | |||
Spectral method | plane diffraction grating | ||||
Integral ball size | Ø 54mm | ||||
Measure the wavelength range | 400nm-700nm | 360nm-740nm | |||
Measure the wavelength interval | 10nm | ||||
Half-wave width | About 10nm | ||||
Reflectivity measurement range | 0-175%, resolution: 0.01% | ||||
Aperture size | MAV:Ø 12mm | MAV:Ø 12mm;SAV:Ø 6mm | |||
measuring aperture | MAV:Ø 8mm | MAV:Ø 8mm;SAV:Ø 3mm | |||
MT | Approximately 0.7 seconds (measurement mode: SCI or SCE) | ||||
Minimum measurement interval | Approximately 1.5 seconds (measurement mode: SCI or SCE) | ||||
repetitiveness | △ Standard deviation within 0.08 of E*ab | △ Standard deviation of E*ab within 0.04 | △ Standard deviation of E*ab within 0.02 | ||
Measurement conditions: After the white calibration is performed, measure the white standard plate 30 times at intervals of 5 seconds | |||||
Instrument table difference | △ Standard deviation of E*ab within 0.40 | △ Standard deviation of E*ab within 0.20 | △ Standard deviation of E*ab within 0.12 | ||
Based on the mean of 12 BCRA series II color plates; MAV SCI; Compared with the measured values of the standard sample under KONICA MINOLTA standard measurement conditions | |||||
standard observer | 2° Angle, 10° Angle | ||||
illuminant | A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65, user-defined light source (two light sources are used for evaluation at the same time) | ||||
video data | Color value / figure, color difference value / figure, spectrum diagram, pass/fail judgment, simulated color | ||||
Color data | L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, and the color differences of these spaces; Munsell (C) | ||||
metric | MI, WI (ASTM E313-73), YI (ASTM D1925), Opacity, user parameters | MI, WI (ASTM E313-73), YI (ASTM E313-73, ASTM D1925), ISO brightness (ISO 2470), WI/Tint (CIE), intensity, coverage, gray scale, 8° gloss, user standard* | |||
The chromaticity equation | ΔE*ab (CIE1976) / ΔE94 (CIE1994) / ΔE00 (CIE2000) / CMC (l:c) / Hunter ΔE / DIN99o | ||||
internal storage | 1,000 target data + 5,100 sample data | ||||
Viewfinder function | Available (with white LED light source) | ||||
display screen | 2.7" color TFT-LCD with a flip vertical browsing mode | ||||
Speak the voice | English, Japanese, German, French, Italian, Spanish, Simplified Chinese, Portuguese, Russian, Turkish, Polish | ||||
port | USB 2.0; Bluetooth (SPP-compatible. Bluetooth module is optional) | ||||
source | Special lithium-ion battery (removable), USB bus power supply (for installation of lithium-ion battery), special AC adapter (for installation of lithium-ion battery) | ||||
Operate the temperature and humidity range | Temperature: 5-40°C; Relative humidity: 80%, or less (at 35°C) without dew | ||||
Storage temperature and humidity range | Temperature: 0-45°C, relative humidity: 80%, or less (at 35°C) without condensation | ||||
Size (length * width * height) | Approximately 81 (W) x 93 (H) x 229 (D) mm | ||||
weight | About 620g | About 630g | |||
standard fitting | Host, AC power adapter, USB cable, wristband, lithium ion battery, calibration board kit | Host, configuration software (available online), AC power adapter, USB cable, anti-static wristband, MAV target cover, SAV target cover (CM-26d), lithium ion battery, flat battery cover, calibration board kit | |||
Optional accessories | Color data software, target hood, Bluetooth module, Bluetooth printer, battery charger |
![]() |