Sign In | Join Free | My burrillandco.com |
|
Ask Lasest Price | |
Model Number : | LR-K008 |
Price : | negotiable |
Brand Name : | Lonroy |
Delivery Time : | 5-8 work days |
Supply Ability : | 200 pieces |
Payment Terms : | L/C, D/A, D/P, T/T, Western Union |
IEC 60587 High Voltage Tracking Erosion Resistance Tester for Insulation Materials
1. Scope of use
Used for electrical and electronic products, household appliances
and their materials for electrical indentation and corrosion
resistance test, simulation in the power frequency (45hz-65hz),
with liquid pollutants and inclined plane test sample, through the
measurement of electrical indentation and corrosion resistance of
electrical insulation materials used in harsh environmental
conditions to assess the level of electrical indentation and
corrosion resistance.
2. Product features
1.7 inch full-color programmable controller touch screen +PLC
control, automatic calibration of liquid flow rate
2. The use of high precision constant flow pump to ensure the
absolute accuracy of the flow rate, the general electromagnetic
valve control can be compared
3. Removable dripping device is adopted to facilitate the cleaning
of excess contaminated liquid
4. The alarm program of super-strong voltage and current protection
can automatically detect the state of the door of the equipment. It
cannot be tested when the door is open to ensure the safety of the
test personnel
1. Test station: 5 (another one is optional)
2. Applied voltage: 0 ~ 6000V± 5% adjustable, when the high voltage
loop current in the test reaches or exceeds 60mA and lasts for 2S,
the relay will operate, the current will be cut off, and the buzzer
alarm will indicate that the test product is unqualified
3. Voltage, start, drain, switch, stop, exhaust and lighting are
all realized on the touch screen. The test data can be stored in
the touch screen
4. Voltage, dripping time, current, dripping velocity, equipment
door state, maximum current, real-time display of experimental
results
5. Filter paper size: according to the standard size requirements,
the filter paper thickness is 0.15 ~ 0.17mm.
6. Drip device: high precision constant current drip device with
adjustable height.
7. The drip device is removable to facilitate the cleaning of
excess contaminated liquid, and will not flow the contaminated
liquid into the box to corrode the box
8. The flow rate of the polluted liquid is between 0.075 and
0.9ml/min, which can be automatically adjusted and adjusted
according to the voltage, saving the trouble of adjusting the flow
rate after the voltage is adjusted
9. It can automatically check the liquid flow rate to ensure the
accuracy of the flow rate and the accuracy of the test (generally,
solenoid valve control in the market cannot guarantee the accuracy
of the flow rate and the uniformity of the liquid).
10. Number of drops, time of drops and test time can be preset.
11. Automatically judge and prompt the state of the door. The door
cannot conduct high pressure test when it is open, which
effectively protects the safety of operators
12. Abnormal test voltage alarm.
13. Voltage over range alarm
14. Current overload protection, current over range alarm.
15. It indicates the peak current value
16. The top is equipped with a silent and anti-reflux exhaust
device, which can discharge the smoke generated by combustion after
the end of the test
17. With lighting function
18. Automatic maintenance at the end of the test
19. Contamination solution: ammonium chloride, isooctyl phenoxy
polyethoxyethanol, non-ionic wetting agent with distilled water or
deionized water mixture.Liquid pollution in (23) 1 ºC resistivity
should be Ω · m (3.95 and 0.05).
20. Electrode: the thickness of upper and lower electrodes is 0.5mm
and 304 stainless material. The dimensions are made according to
the requirements of standard sizes.
Power requirements: AC220 (10%) V/50HZ, 3KW Overall dimensions: 1350 * 700 * 1600mm |
Standard GB6553-2014 test method for evaluating resistance to electrical indentation and corrosion of electrical insulating materials used in harsh environmental conditions (IEC60587:2007, IDT)
![]() |